Precautions for storage of molecular sieves:
1. Molecular sieves are highly hygroscopic. It should not be directly exposed to the air during storage and should be placed in a dry place. Molecular sieves that have been stored for a long time and have absorbed moisture should be regenerated before use.
2. Molecular sieves should avoid oil and liquid water. Oil can clog the pores of molecular sieves. Especially during regeneration, the oil may be carbonized, causing clogging of the pores. For gases containing oil, the oil, gas, and oil and water should be separated first before proceeding to the molecular sieve tower. Since the molecular sieve releases heat when adsorbing water, a large amount of heat will be released when liquid water directly contacts the molecular sieve. Danger may occur or the performance of the molecular sieve may be damaged.
3. When the molecular sieve tower working under pressure is switching between regeneration, the internal pressure of the tower should be slowly reduced. If the pressure reduction speed is too fast, the molecular sieve particles may be broken and pulverized. The higher the regeneration temperature, the safer the regeneration will be, but at the same time, the energy consumption of regeneration will be greater, and the life of the molecular sieve may also be shortened. Therefore, the regeneration temperature is more suitable between 200-350°C. The regeneration temperature should generally not exceed 600°C, otherwise the molecular sieve may lose activity.
Things to note when packaging molecular sieves:
1. Because alumina and molecular sieves are irritating, you need to wear gloves, masks, and protective goggles during the filling process. You must apply for a tower and tank entry permit to enter the adsorber. No single person is allowed to enter, and you must wear protective equipment when entering. And equipped with air breathing apparatus.
2. The adsorbent has strong water absorption and can generate heat when in contact with water, which can heat the water to the boiling point. Therefore, it should not be in contact with the skin, especially it should not be put in the mouth or splashed into the eyes.
3. Wear safety belts during loading to prevent falling.
4. When entering, conduct a component analysis first. O2 is between 19 and 23%. You should wear clean and oil-free work clothes and stand on the prepared wooden board to prevent damage. Contamination absorbers and screens.